Containment Closure Time Following Loss of Cooling Under Shutdown Conditions of YGN Units 3&4

  • Seul, Kwang-Won (Korea Institute of nuclear Safety, Advanced Reactor Department) ;
  • Bang, Toung-Seok (Korea Institute of nuclear Safety, Advanced Reactor Department) ;
  • Kim, Se-Won (Korea Institute of nuclear Safety, Advanced Reactor Department) ;
  • Kim, Hho-Jung (Korea Institute of nuclear Safety, Advanced Reactor Department)
  • Published : 1998.05.01

Abstract

The YGN Units 3&4 plant conditions during shutdown operation were reviewed to identified the possible even scenarios following the loss of shutdown cooling. The Thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior, From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determined the containment closure time to prevent the uncontrolled released of fission products to atmosphere, These data provide useful information to the abnormal procedure to cope with event.

Keywords