Applied Voltage Dependence of the Displacement Characteristics on The Cymbal Actuator

심벌 액츄에이터의 변위특성에 대한 인가전압 의존성

  • 최성영 (한국교원대학교 기술교육과) ;
  • 김진수 (한국교원대학교 기술교육과)
  • Published : 1998.11.01

Abstract

In this study, the cymbal actuators with brass and bronze endcap at various endcap thickness were fabricated, and then the displacement vs applied voltage relation and position from the center of endcap relation were investigated The displacement values of all cymbal actuator were measured using laser vibrometer. The displacement of the cymbal actuator was increased linearly with increasing applied voltage. The cymbal actuator with 0.15mm thick brass endcap show approximately 1.3$\mu\textrm{m}$ displacement more than cymbal actuator with uniformly thick bronze endcap. The displacement about 3mm in diameter at the center of the endcap was uniform and rapidly decreased away from 3mm in diameter at the center of the endcap.

Keywords