Design of ALIP with Flowrate of 40 I/min for the Removal of Residual Heat

잔열 제거용 40 I/min급 환단면 선형유도전자펌프의 설계

  • Kim, H.R. (Korea Atomic Energy Research Institute) ;
  • Nam, H.Y. (Korea Atomic Energy Research Institute) ;
  • Kim, Y.G. (Korea Atomic Energy Research Institute) ;
  • Choi, B.H. (Korea Atomic Energy Research Institute) ;
  • Kim, J.M. (Korea Atomic Energy Research Institute) ;
  • Hwang, J.S. (Provincial College of Damyang)
  • Published : 1998.11.28

Abstract

EM(Electro Magnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). In the present study. pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.