대한전기학회:학술대회논문집 (Proceedings of the KIEE Conference)
- 대한전기학회 2000년도 하계학술대회 논문집 C
- /
- Pages.2089-2091
- /
- 2000
커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로
Low-cost crowbar system and protection scheme in capacitor bank module
- Rim, Geun-Hie ;
- Cho, Chu-Hyun ;
- Lee, Hong-Sik ;
- Pavlov, E.P.
- 발행 : 2000.07.17
초록
Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.
키워드