A Study on the Fan and Scroll for Ventilation

배기용 Fan Scroll에 대한 연구

  • 송성배 (LG전자 디지털 어플라이언스 연구소 요소기술팀) ;
  • 박성일 (LG전자 디지털 어플라이언스 연구소 요소기술팀) ;
  • 이준세 (LG전자 디지털 어플라이언스 연구소 요소기술팀)
  • Published : 2000.06.22

Abstract

In the Over-The-Range, the outlet size is limited by the industrial standards. Therefor to enlarge the volume of cavity, the installation height of ventilation fan is become small, the system resistance is higher than before. For that reason, the important design variables such as the diameter of a fan, the scroll expansion angle, etc. which play the significant role on flow rate and noise, are confined. In this study, we made an experiment of the diameter of fans relation to scroll expansion angle and investigated flow rate of the length of fans in enlarged cavity volume of OTR, and then we designed the new scroll to improve the flow rate and noise level. As a result, flow rate increased to 110% compared to current scroll and the blade passing frequency of a fan is disappeared by inclined cut-off shapes.

Keywords