Multiple Microphone Technique for a Direct Measurement of In-duct Acoustical Parameters

다수의 마이크를 이용한 관내 음향 변수의 직접 측정법

  • 장승호 (한국과학기술원 기계공학과 소음진동제어연구센터) ;
  • 이정권 (한국과학기술원 기계공학과 소음진동제어연구센터)
  • Published : 2000.06.22

Abstract

Nowadays, the two microphone method is accepted as the standard as specified in ASTM E1050-90 for measuring in-duct acoustic properties. However, research results on using the least square method with multiple measurement points and broadband excitation have been reported for enhancing the frequency response of the two microphone method. In this paper, the effects of varying the relative measurement positions on errors in the estimation of the acoustic quantities is studied for the multiple microphone method. Both of the theoretical and experimental results show that, among every possible sensor positioning configurations, the equidistant positioning of sensors yields the smallest error within the effective measurement frequency range. In addition, it is noted that the measurement accuracy can be increased and the effective frequency range can be widened by increasing the number of equidistant sensors. Measurement examples are shown and the results support the findings.

Keywords