현장적용 투수성 콘크리트의 배합조건 결정에 관한 실험적 연구

A Study on the Determination of mix Proportion of Water-Permeable Concretes for Site Application

  • 김봉찬 (정회원, 전북대학교 건축공학과) ;
  • 은재기 (정회원, 전북대학교 건축공학과) ;
  • 김완기 (정회원, 전북대학교 건축공학과 강사, 공박, 공업기술연구소) ;
  • 소양섭 (정회원, 전북대학교 건축·도시공학부 교수·공업기술연구소)
  • 발행 : 2000.04.01

초록

The purpose of this study is to examine the physical properties of water-permeable concretes. The water-permeable concrete with cement-aggregate ratios of 1:3.5 to 1:6.0 and two type of coarse aggregate size of 8~13 and 13~18mm used OPC(ordinary portland cement) as a binder and superplasticizer are prepared, and then tested for flexural strength, compressive strength, compressive strength, continuous void percentage and coefficient of water permeability. It is concluded from the test result that the superior flexural and compressive strengths, coefficient of water permeability and continuous void percentage of water-permeable concretes that use OPC were obtained at cement-aggregate ratios of 1:3.2, 1:6.0 respectively, The water-permeable concretes with coarse aggregate of 8~13 and 13~18mm size used OPC as a binder havinga flexural strength of 24.81~45.56kgf/$\textrm{cm}^2$, 21.99~40.62kgf/$\textrm{cm}^2$, a compressive stength of 93.63~ 242kgf/$\textrm{cm}^2$, 114.8~191.7.kgf/$\textrm{cm}^2$, a coefficient of permeability of 0.59~1.85kgf/$\textrm{cm}^2$, 0.73~ 2.25kgf/$\textrm{cm}^2$, and a continuos void percentage of 16.6~26.32%, 13.52~24.35% respectively during 28 curing days.