This study was conducted to investigate the seismic behavior assessment of circlular-tied bridge piers, particularly with regard to assessing the displacement ductility. The experimental variables of bridge piers test consisted of transverse steel details, amount and spacing different axial load levels etc. The test results indicated that reinforcement concrete bridge piers with confinement steel by the code specification exhibited sufficient ductile behavior and seismic performance. Aldo, it is found that current seismic design code specification of confinement steel requirements may be revised.