Capacities and Failure Modes of Transfer Girders in the Upper-Wall and Lower-Frame Structures having different Detailing

주상복합구조의 전이보 상세에 따른 성능과 파괴모드

  • 이한선 (고려대학교 건축공학과) ;
  • 김상연 (고려대학교 박사과정, 대한주택공사) ;
  • 고동우 (고려대학교 건축공학과) ;
  • 권기혁 (서울시립대 건축공학과) ;
  • 김민수 (서울시립대 건축공학과)
  • Published : 2000.10.01

Abstract

This paper presents the results of tests performed on the transfer girders which have been generally used between upper walls and lower frames in the hybrid structures. The 8 specimens were designed using (1) ACI method, (2) strut-tie model, and (3) X-type shear reinforcement cage. The capacities of the specimens are in general larger than the design values except the one designed according to strut-tie model. The reason for this difference seems to be due to the arbitrary allocation of transferred shear force to the path of direct compression strut and the path of indirect strut and tie. The failure modes turn out toe be (1) shear failure at critical shear zone, (2) compressive concrete crushing in the diagonal strut in the shear zone of transfer girder, and (3) compressive concrete crushing in the corner of upper wall.

Keywords