Temperature-Viscosity Characteristics of Hydrous and Anhydrous Electro-Rheological Fluids

함수계와 비수계 ER유체의 온도-점도 특성

  • 이진우 (경남대학교 대학원 기계공학과) ;
  • 장성철 (경남대학교 대학원 기계공학과) ;
  • 염만오 (경남대학교 기계자동화공학부) ;
  • 김도태 (경일대학교 기계공학부) ;
  • 박재범 (경남대학교 유공압제어연구실, 부산인력개발원)
  • Published : 2002.04.01

Abstract

This paper describes the properties of Temperature-Viscosity characteristics of hydrous and anhydrous ER fluids containing starch and titanium particle in silicone oil. ER effects arise from electrostatic forces between the starch particles and titanium particles dispersed in the electrically insulating silicone oil induced when electric field is applied. ER fluids under electric field have been found to provide resonable estimates of ER fluid viscosity variation characteristics. Yield shear stress of the ER fluids were measured on the couette cell type rheometer as a function of electric fields. The outer cup is connected to positive electrode(+) and bob becomes ground(-). The electric field is applied by high voltage DC power supply. In this experiment shear rates were increased from 0 to 200/equation omitted/ in 2 minutes.

Keywords