Realtime Detection of Damage in Composite Structures by Using PVDE Sensor

압전고분자 센서를 이용한 복합재 구조의 실시간 손상탐지

  • ;
  • Y. A. Dzenis (University of Nebraska-Lincoln)
  • 권오양 (인하대학교 기계공학부) ;
  • Published : 2002.10.01

Abstract

Polyvinylidene di-fluoride (PVDF) film sensor appeared to be practically useful for the structural health monitoring of composite materials and structures. PVDF film sensors were either attached to or embedded in the graphite/epoxy composite (CFRP) samples to detect the fatigue damage at the bondline of single-lap joints or the tensile failure of unidirectional laminates. PVDF sensors were sensitive enough to detect and determine the crack front in linear location since composites usually produce very energetic acoustic emission (AE). PVDF sensors are extremely cost-effective, as flexible as other plastic films, in low profile as thin as a few tens of microns, and have relatively wide-band response, all of which characteristics are readily utilized for the structural health monitoring of composite structures. Signals due to fatigue damage showed a characteristics of mode II (shear) type failure whereas those from fiber breakage at DEN notches showed that of mode I (tensile) type fracture.

Keywords