Retrofit Method of Damaged Flexural Wall

피해가 발생된 휨벽체의 내진보강에 관한 연구

  • 서수연 (한양대 STRESS) ;
  • 이용택 (한밭대학교 건축공학부) ;
  • 이현호 (동양대학교 건축ㆍ실내디자인학부) ;
  • 이리형 (한양대학교 건축공학부) ;
  • 천영수 (대한주택공사 주택도시연구원) ;
  • 양지수 (대한주택공사 건축설계처)
  • Published : 2002.05.01

Abstract

An experimental work is performed to evaluate the retrofit method of damaged flexural walls. For two flexural walls damaged up to almost failure, reinforcements yielded and concrete below height of 1d are replaced with new reinforcements and steel fiber concrete, respectively. In order to evaluate the effectiveness of Aramid sheet for retrofitting walls, Aramid sheet is also, attached to longitudinal direction and rolled horizontal direction of one wall specimen. Horizontal cyclic loads are applied to the top of the specimen with constant axial load. Test result showed that retrofitting with steel fiber concrete after replacing reinforcements can not afford to recover 100% of the wall capacity before damage. However, the capacity of walls could be sufficiently strengthened by using Aramid sheet.

Keywords