The Limit and Application of Two-microphone Impedance Tube Method to the Sound Transmission Loss Measurement of Sound Isolation Materials

차음재의 음향투과손실 측정에 Two-Microphone Impedance Tube Method의 적용과 한계

  • 이승 (서울산업대학교 산업대학원 기계공학과) ;
  • 안민홍 ((주) 혜인) ;
  • 이동훈 (서울산업대학교 기계공학과)
  • Published : 2002.05.01

Abstract

This study describes the limit and application of the two-microphone impedance tube method to the sound transmission loss measurement of several sound isolation materials with different physical properties. For the sound isolation materials having small flexural rigidity, it is shown that the two-microphone impedance tube method is validated to practically measure the sound transmission loss. For the sound isolation materials having large flexural rigidity, on the other hand, it is found that the two-microphone impedance tube method is no longer valid to measure the sound transmission loss because the regions of resonance and mass law are moved into the higher frequencies. In addition, in order to accurately measure the sound transmission loss of sound isolation materials, their size should be decided based on the consideration of the effect of acoustic excitation on their vibration response.