Measurement of wall charge characteristics for three-electrode AC PDP

  • Yoon, Sang-Jin (Digital PDP Division, LG Electronics Inc.) ;
  • Yang, Hee-Chan (Division of Electrical and Computer Engineering, Pohang University of Science and Technology) ;
  • Kang, Seong-Ho (Division of Electrical and Computer Engineering, Pohang University of Science and Technology) ;
  • Ryu, Jae-Hwa (Division of Electrical and Computer Engineering, Pohang University of Science and Technology) ;
  • Kang, Bong-Koo (Division of Electrical and Computer Engineering, Pohang University of Science and Technology)
  • Published : 2002.08.21

Abstract

This paper proposes a real-time wall charge measurement circuit for three-electrode AC PDP. It includes a charge-compensation network, current-integrating capacitors, initializing switches, and an op-amp. With this equipment, we measure the wall charge variations for the effects of sustain voltage, sustain pulse width, sustain frequency, and neighboring cells.

Keywords