A Case Study on the Leakage in Concrete Face Rockfill Dam

콘크리트 표면차수벽형 석괴댐(CFRD)의 누수특성에 관한 사례연구

  • 방돈석 (한국시설안전기술공단 댐항만실) ;
  • 신창건 (한국시설안전기술공단 기술개발실) ;
  • 이강용 (한국시설안전기술공단 댐항만실) ;
  • 안상로 (한국시설안전기술공단 댐항만실)
  • Published : 2003.03.01

Abstract

The leakage quantity through concrete facing of Concrete Face Rockfill Dam(CFRD) is very small due to its low permeability of intact concrete. Even though the concrete facing is well designed and constructed, fine cracks can be generated due to effects of thermal and drying shrinkage. Therefore, it can be said that the leakage from the CFRD is subjected to not permeability of intact concrete but poor joints, cracks and foundation rocks. The Safety of a dam on leakage was evaluated based on the comparison between apparent permeability estimated and leakage quantity measured. The above method can be concluded to give a good direction for the evaluation of safety on CFRD in maintenance aspects as design and construction technology is improved with the accumulation of leakage data.

Keywords