Shear Behavior of Wide Beam-Column Joints with Slab

슬래브가 있는 넓은 보-기둥 접합부의 전단거동

  • 안종문 (CS구조엔지니어링) ;
  • 최종인 (한양대학교 STRESS) ;
  • 신성우 (한양대 건축학부) ;
  • 이범식 (대한주택공사 주택도시연구원) ;
  • 박성식 (대한주택공사 주택도시연구원) ;
  • 양지수 (대한주택공사 건축설계처)
  • Published : 2003.05.01

Abstract

An experimental investigation was conducted to study the behavior of high-strength RC wide beam-column joints with slab subjected to reversed cyclic loads under constant axial load. Six half scale interior wide beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including three specimens without slab and three specimens with slab. The primary variables were compressive strength of concrete($f_ck$=285, 460kgf/$cm^2$), the ratio of the column-to-beam flexural capacity($M_r$=$\Sigma M_c / \Sigma M_b$ ; 0.77 -2.26), extended length of the column concrete($l_d$ ; 0, 12.5, 30cm), ratio of the column-to-beam width(b/H ; 1.54, 1.67). Test results are shown that (1) the behavior of specimen using high-strength concrete satisfied for required minimum ductile capacity according to increase the compressive strength, (2) the current design code and practice for interior joints(type 2) are apply to the wide beam-high strength concrete column.

Keywords