An Experimental Study on the Performance Evaluation of Structural Synthetic Fiber-Reinforced Shotcrete

구조용 합성섬유보강 숏크리트의 성능평가에 관한 실험연구

  • 오병환 (서울대학교 공과대학 토목공학과) ;
  • 최승원 (서울대학교 공과대학 토목공학과) ;
  • 박대균 (서울대학교 공과대학 토목공학과) ;
  • 한일영 (SK 건설기술연구소) ;
  • 김방래 (SK 건설기술연구소) ;
  • 신용석 (현대산업개발 토목설계팀)
  • Published : 2003.05.01

Abstract

The cement-based composites have relatively low tensile strength and toughness. The fiber addition is one of the most important ways of increasing the toughness of concrete. The steel fibers have been used conventionally in the shotcrete of tunnel lining. Recently, the structural synthetic fibers were developed and used frequently in some actual tunnel shotcreting in foreign countries. Now types of synthetic fibers have been developed in this study. The purpose of this study is to explore the strength and toughness characteristic of the concrete reinforced with synthetic fibers developed in this study. The result were compared with those of steel fiber reinforced concrete. It is seen that the performance of synthetic fiber reinforced concrete is good as much as that of steel fiber reinforced concrete, while the synthetic fibers have advantages in corrsion resistance and economy.

Keywords