A Study on the Responsibility of Thin film instantaneous surface temperature probe of a Dual-pipe structure

이중관 구조 박막형 순간온도 프로브의 응답성에 관한 연구

  • 최석렬 (경희대학교 기계공학과 대학원) ;
  • 박경석 (경희대학교 테크노공학대학)
  • Published : 2003.12.12

Abstract

The measurement study of instantaneous temperature at combustion chamber wall and the temperature of combustion gas has been under lots of research and development to conclude the temperature process in internal combustion engine for combustion characteristics analysis. The measurement with fast responsibility should be used for temperature measurement inside combustion chamber wall since temperature of wall changes, due to the various gas temperature, irregularly during the combustion. Therefore, thin film instantaneous surface temperature probe, which characterizes the fastest and the most accurate responsibility among contact typed temperature measurement, was used for the experiments. This new thin film instantaneous surface temperature probe improved the problems of noise and durability. The optimal coating thickness of thin film instantaneous surface temperature probe was proven to be $10{\mu}m$ for the best responsibility and durability. It also allowed the stable temperature measurement be taken up to $1,200^{\circ}C$ and proven to be read possibly from the combustion chamber wall.

Keywords