Experimental Study on CHF Enhancement of Plate by Ultrasonic

초음파에 의한 평판에서의 임계열유속 증진에 대한 실험적 연구

  • Published : 2003.04.23

Abstract

Augmentation of CHF by ultrasonic is experimentally studied under subcooling pool boiling condition. Experiment is carried out for downward-facing plate with and without the ultrasonic. The working fluid is distilled water. Experimental apparatus is composed of a bath, power supply, test section, ultrasonic generator, DAQ system. Experiment is performed with the subcooling temperature of $5^{\circ}C$, $20^{\circ}C$, $40^{\circ}C$ and the inclined angle of $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $45^{\circ}$, 90. From the experimental results, it is found that ultrasonic effect enhances CHF of the downward-facing plate. As increasing the degree of subcooling, the rate of CHF increase is enhanced. As increasing the inclined angle, the rate of CHF increase decreases. Also, we can see that the heat transfer mechanism of CHF augmentation is closely connected with the dynamic behavior of bubble generation and departure.