A Study of High Particle Collection Efficiency of Cyclone

고효율 사이클론의 집진효율에 관한 연구

  • 정진도 (호서대학교 환경공학과) ;
  • 이상권 (호서대학교 대학원 환경공학과) ;
  • Published : 2003.04.23

Abstract

For a reasonable analysis of grade efficiency of cyclone separator, in-line measurements of particle size and particle concentration are needed. The purpose of this study is to define the correlation of measurement data and to measure grade efficiency and pressure drop. The authors adapted that the grade efficiency could be calculated directly from the counted particle numbers. The problem of collection efficiency calculation was different from counting rate of aerosol counters under the same conditions. It is important factor to use the rate of the particle counters to obtain reliable results. Therefore, the authors should use and calculate compensation factor considering sensitivity of aerosol counters, gas velocity and concentration affect higher 30% than originally measured grade efficiency. As the pressure drop and grade efficiency increase, as flow rate increase and then also pressure drop and grade efficiency increase.

Keywords