Air Influx Characteristics of Turbo Pumps

공기 유입시의 터보펌프 특성

  • 김유택 (한국해양대학교 기관시스템공학부) ;
  • 남청도 (한국해양대학교 기관시스템공학부) ;
  • 강호근 (경상대학교 기계항공공학부) ;
  • 이영호 (한국해양대학교 기계 정보공학부)
  • Published : 2004.12.01

Abstract

A screw-type centrifugal pump was manufactured to carry solids primarily and its impeller has a wide flow passage. However, the effect of flow passage shape on delay of the choke due to entrained air has not been clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For that reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that loss of pump head from single-phase flow to the choke due to air entrainment new the best efficiency point was large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

Keywords