단상 및 이상유동 유량 계측을 위한 평균 양방향 유동 튜브 개발

Development of an Average Bi-directional Flow Tube for the Measurement of Single and Two phase Flow Rate

  • 윤병조 (한국원자력 연구소 열수력 안전 연구부) ;
  • 강경호 (한국원자력 연구소 열수력 안전 연구부) ;
  • 어동진 (한국원자력 연구소 열수력 안전 연구부) ;
  • 백원필 (한국원자력 연구소 열수력 안전 연구부)
  • 발행 : 2004.12.01

초록

Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. The suggested instrumentation was tested in the air-water vertical test section which has 80mm inner diameter and 10m length. The flow tube was installed at 120 of L/D from inlet of test section. From the test, single air and water flow rate was measured successfully. For the emasurement of two phase flow rate, Chexal drift-flux correlation was used. In the test a new correlation of momentum exchange factor was suggested. The test result shows that the suggested instrumentation using the measured void fraction and Chexal drift-flux correlation can predict the mass flow rates within $10\%$ error of measured data.