The plan of depreciation vortex developing a Pump suction Pipes through Sump model test

수리모형실험을 통한 펌프 흡입배관부 보텍스 현상 저감방안

  • Published : 2004.12.01

Abstract

In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, my introduce air into pun, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. This study investigated experimentally the formation of the vortex to understand the mechanism of vortex formation and to prevent the formation of vortex in the sump model using by the model test and PIV tool. Sump model was manufactured to 1/8 scale with the drawing of W intake pumping station. from the results of model test and PIV, the vortex were occurred the in the whole section. Thus, sump model tests with the anti-vortex device might be considered to prevent the formation of vortex in the sump model.

펌프장 흡입수조에서 발생되는 보텍스의 구조를 Sump Model Test와 PIV 방법을 수행하여 보텍스 발생여부를 검증한 결과는 아래와 같다. 1) 현장조사의 결과 취수장 대부분의 흡수정 구조가 유체역학적으로 보텍스를 발생시키는 구조였음을 알 수 있었으며 흡수정의 형태를 흡입구와 수문이 일직선으로 되어 있는 토목구조를 가진 펌프장이 경유는 보텍스 발생이 비교적 적었음을 알 수 있었다. 이는 토목구조의 설계가 펌프과정에 따른 흡수정 내의 유동장을 고려하여 볼 때 매우중요하다는 것을 알 수 있다. 2) JSME S 004-1984를 토대로 1/8 모델내에서 모형수리실험을 수행한 결과 현장에서 발견된 결과와 같이 예측되었다. 또한, 모든 상사조건 일치에서 수위나 운전대수 및 호기조합에 따라 정도의 차이는 있으나 모든 경우에 보텍스가 심하게 발생하고 있음을 알 수 있었다. 3) PIV 실험에서 볼 수 있듯이 자유표면 보텍스는 $\sharp$1 호기와 $\sharp$3 호기에서 주로 발견되었는데 이는 $\sharp$3 호기 흡입구 바로 전방에 있는 취수구의 영향으로 강한 회전흐름이 수조 내에서 형성되기 때문으로 보여진다. 4) 보텍스의 발생은 펌프 소음발생 임펠러 수명 및 성능에 나쁜 영향을 주기 때문에 반드시 Anti Vortex Device를 설치하여 보텍스의 발생을 저감시켜야 한다.

Keywords