Analysis of CWR track on the High-Speed Railway Bridges considering the Expansion Length of Bridge Deck

고속철도교량의 온도신축길이 변화를 고려한 교량상 장대레일의 거동 해석

  • 강재윤 (한국건설기술연구원 구조연구부) ;
  • 김병석 (한국건설기술연구원 구조연구부) ;
  • 곽종원 (한국건설기술연구원 구조연구부) ;
  • 최은석 (한국건설기술연구원 구조연구부) ;
  • 진원종 (한국건설기술연구원 구조연구부)
  • Published : 2004.10.01

Abstract

Currently, in the design criteria for the high speed railway bridges, the maximum distance between bridge expansion joint is limited to 80m using a continuous welded mil, in order to limit the additional stress in the rail due to the rail-bridge interaction. In the past study on the resonance effect of HSR train, it is known that the reduction of resonance and dynamic responses of bridge deck occurs at the specific expansion length of 28.05m and 46.75m. In this study, the stability of track structure on the HSR bridges with expansion length of 90m has checked by finite element method. And the track behavior including mil stresses and relative displacements are compared to the current state of track structures on the bridge system with 80m long expansion length.

Keywords