Disinfection of harmful organism for ballast water using electrolytic treatment system

전해처리를 통한 밸러스트수의 유해생물 살균처리

  • 박상호 (한국해양대학교 토목환경시스템공학부) ;
  • 김인수 (한국해양대학교 토목환경시스템공학부)
  • Published : 2004.04.01

Abstract

Ballast water from ship harmful microorganism sterilized use of electrolytic sterilization system. The experimental methods were use of peristaltic flow pump upward on electrode pole. Due to reaction time, HRT were unlike microorganism on flow rate. In electrolysis, dioxide iridium coated titanium(Ti/IrO$_2$) and stainless steel plate were used for anode and cathode respectively. Current density controls make use of D.C Power supply on 250V 100Amper. Experimental use of current density between 0.1 and 0.5A was able to disinfect microorganism at 5 seconds by the reaction time. This study shows that the electrolyzed water has a potential for the sterilization of ballast water.

선박에서 발생되는 밸러스트수를 처리하기 위하여 수중에 포함되어 있는 미생물을 북극전해처리시스템을 이용하여 살균처리 하였다. 전해처리시스템에 유입되는 시료는 정량펌프를 사용하여 상향류로 전극판 사이를 통과하도록 하였으며, 반응시간별로 유량을 조절하여 체류시간을 다르게 하였다. 양극판은 티타늄에 이산화이리듐을 전착한 Ti/IrO$_2$ 극판으로 하였으며, 음극판은 스테인리스 스틸판을 사용하였다. 전원공급은 최대 전압이 250V, 전류가 100Amper의 맥류가 전혀 없는 트랜지스트 평활회로를 사용한 D.C. Power Supply를 사용하여 전류밀도를 조절하여 운전하였다. 반응시간에 따라 전류밀도를 0.1~l.0A사이로 변화를 주어 실험한 결과 5초 이내에 대부분의 미생물이 사멸됨을 확인 할 수 있었고 연구결과를 통하여 발라스트수 처리에 적용 가능한 기술임을 알 수 있었다.

Keywords