Non-destructive Evaluation to Assess Leak of Bond in Brazed Large Generator ″ C″ -Coil by Ultrasonic Retro-Reflection

초음파 Retro-Reflection에 의한 대형 발전기용 C-Coil Brazed부의 비파괴적 평가

  • 성운학 (두산중공업 기술연구원 소재개발연구팀) ;
  • 양병일 (두산중공업 기술연구원 소재개발연구) ;
  • 김정태 (두산중공업 기술연구원 소재개발연구팀)
  • Published : 2004.05.01

Abstract

One set of rotor coils is required per each large generator rotor assembly, Rotors consist of two directly opposing poles. Each pole requires from 5 to 9 coils. Each coil is made up of two halves identified on the connection end. These coil halves will be joined together by butt brazing process during subsequent rotor assembly. Each half coil is made up of typically 4 to 9 layers of copper conductors. Because of Generator rotor is rotated very high speed with 3,600RPM, the quality soundness of brazed joints is very important at each coil. But, it is very difficult to be optimized non-destructive evaluation, because c-coil has the long shape and evaluation is to be done assembled condition. In this paper introduce newly developed inspection process and acceptance standards for the ultrasonic inspection of " C" coil butt braze. This inspection system is a semi-automatic ultrasonic flaw detector with data acquisition and retention capable of assessing the relative lack of bond of brazed butt joints

Keywords