Experimental Study On Power Flow Analysis of Vibration of Simple Structures

단순구조물 진동에 대한 파워흐름해석법의 실험적 연구

  • 이병철 (수원대학교 기계공학과) ;
  • 길현권 (수원대학교 기계공학과) ;
  • 이용현 (수원대학교 기계공학과) ;
  • 이효행 (수원대학교 기계공학과) ;
  • 홍석윤 (서울대학교 조선해양공학과)
  • Published : 2004.11.01

Abstract

The power flow analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiment has been performed to observe the analytical characteristics of the power flow analysis of the vibration of a plate. In the experiment, the loss factor of the plate and the input mobility at a source point have been measured. The data for the loss factor has been used as the input data to predict the vibration of the plate with PFA. The frequency response functions have been measured over the surface of the plate. The comparison between the experimental results and the predicted results for the frequency response functions showed that PFA can be an effective tool to predict structural vibration in medium-to-high frequency ranges.

Keywords