Waterhammer in Transmission Pumping Station with Ball Valve

볼밸브를 사용한 송수펌프장에서의 수격현상

  • 김경엽 (한국산업기술대학교 기계공학과) ;
  • 김점배 (서울특별시 상수도사업본부)
  • Published : 2004.04.28

Abstract

The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure. the hydraulic transients occur as a result of the sudden change in velocity. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations. in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

Keywords