Experimental investigation of Geyser boiling in Thermosyphon for Solar Collector

태양열 집열용 써모사이폰의 Geyser boiling에 대한 실험적 연구

  • Hong, J.K. (Department of Mechanical Engineering, Gyeongsang National University) ;
  • Bae, C.H. (Department of Mechanical Engineering, Gyeongsang National University) ;
  • Chung, K.T. (Department of Mechanical Engineering, Gyeongsang National University) ;
  • Suh, J.S. (Department of Mechanical Engineering, Gyeongsang National University)
  • 홍정규 (경상대학교 대학원) ;
  • 배찬효 (경상대학교 대학원) ;
  • 정경택 (경상대학교 대학원) ;
  • 서정세 (경상대학교 기계항공공학부, 항공기부품기술연구센터)
  • Published : 2004.11.03

Abstract

This study has been carried out to investigate thermosyphon's geyser boiling phenomenon used to solar collector. evaporator section of thermosyphon used to solar collector is very much longer than that of condenser section. From the results from this study, Geyser boiling's cycle depends on cooling water, tilt angle and the applied heat load at the evaporator. In this study, according to heat load, the geyser boiling frequency is lower, but the amplitude higher. For the high tilt angle of heat pipe, the frequency and amplitude are lower and higher in the evaporator region, respectively. Whereas, these phenomena is in contrast in the condenser region.