Properties of Fire Endurance of High Performance RC Column by Loaded Heating Test

고성능 RC 기둥의 재하가열시험에 의한 내화 특성

  • 김경민 (두산산업개발(주) RC연구개발팀) ;
  • 김기훈 (청주대학교 대학원) ;
  • 황인성 (아세아시멘트(주) 연구개발팀) ;
  • 이재삼 (두산산업개발(주) RC연구개발팀) ;
  • 이성연 (두산산업개발(주)기술연구소) ;
  • 한천구 (청주대학교 건축공학부)
  • Published : 2005.05.01

Abstract

This study discusses spalling and fire enduring performance of high performance concrete (HPC) RC column subjected to loading under heating for 3 hours. According to the test, both the plain concrete and the concrete attached with fire enduring PC panel exceed allowable temperature after 60 minutes due to the exposure of steel bar and falling off of concrete resulting from severe spalling failure. It leads to buckling of main bar and at the same time, occurrence of collapse of plain HPC column member is observed after 2 hours and 1 hour 40 minutes's exposure to fire, respectively. On the other hand, HPC applying both PP fiber of 0.1$\%$ by mass of concrete and PP fiber+lateral confinement by metal lath maintains their original cross section, which is satisfied with the 3 hours fire endurance criteria, by discharging internal vapour pressure and enhanced lateral confinement force.

Keywords