Field Test on IEC60364-4-44 for the Application in Korean distribution system

IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험

  • Nam, Kee-Young (K.E.R.I.(Korea Electrotechnology Research Institute) Power Research Lab, Underground Systems Group) ;
  • Choi, Sang-Bong (K.E.R.I.(Korea Electrotechnology Research Institute) Power Research Lab, Underground Systems Group) ;
  • Jeong, Seong-Whan (K.E.R.I.(Korea Electrotechnology Research Institute) Power Research Lab, Underground Systems Group) ;
  • Lee, Jae-Duck (K.E.R.I.(Korea Electrotechnology Research Institute) Power Research Lab, Underground Systems Group) ;
  • Ryoo, Hee-Suk (K.E.R.I.(Korea Electrotechnology Research Institute) Power Research Lab, Underground Systems Group) ;
  • Kim, Dae-Kyeong (K.E.R.I.(Korea Electrotechnology Research Institute) Power Research Lab, Underground Systems Group)
  • 남기영 (한국전기연구원 전력연구단 지중시스템 연구그룹) ;
  • 최상봉 (한국전기연구원 전력연구단 지중시스템 연구그룹) ;
  • 정성환 (한국전기연구원 전력연구단 지중시스템 연구그룹) ;
  • 이재덕 (한국전기연구원 전력연구단 지중시스템 연구그룹) ;
  • 류희석 (한국전기연구원 전력연구단 지중시스템 연구그룹) ;
  • 김대경 (한국전기연구원 전력연구단 지중시스템 연구그룹)
  • Published : 2006.07.12

Abstract

The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

Keywords