The Usability of Zinc Electrode using Wireless Measuring System of Electric Potential
무선전위측정시스템에 사용하는 아연전극 활용성 검토
- Lee, Jong-Rark (Institute of Gas Technology Training, Korea Gas Safety Corporation) ;
- Leem, Sa-Hawn (Institute of Gas Technology Training, Korea Gas Safety Corporation) ;
- Kim, Sang-O (Technology consulting centeri Korea Gas Safety Corporation)
- Published : 2006.11.16
Abstract
This study is to make a basic study if solid zinc (Zn) can be used for buried reference electrode, so we examined the adequacy of zinc as reference electrode by using zinc which showed regular electrode for buried period. The deference of electric potential if zinc electrode for corrosion factor such as soil resistivity or pH didn't show fixed trend and there was no clear trend on the change of measurement period. From field test, it is known that the natural electric potential difference of CSE electrode and zinc electrode is 1,100mV, but the electric potential of zinc electrode for CSE electrode in the natural soil and copying soil was 1,094~1,158mV. There was no fixed trend on the change of measurement period and electric potential difference of zinc electrode for corrosion factors such as soil resistivity or pH. Consequently, there was 40~60mV of electric potential difference in every copying soil during the experiment measurement.
Keywords