Cause Analysis of Level Measurement Error in Steam Generator of Nuclear Power Plant

원자력발전소의 증기발생기 수위계측 오차 원인분석

  • 이광대 (한국전력공사 전력연구원 I&C그룹) ;
  • 오응세 (한국전력공사 전력연구원 I&C그룹) ;
  • 양승옥 (한국전력공사 전력연구원 I&C그룹)
  • Published : 2006.10.27

Abstract

The differential pressure method has been used in the level measurement of steam generator in nuclear power plant. Two sensing lines from a steam generator to a pressure transmitter are needed to measure the high pressure and low pressure. The fluid conditions in the sensing line require the uniform phase with no bubbles and the slope of sensing line should be installed with forward slope. The expansion of the bubble volume according to the upper pressure and the reverse slope of sensing lines explain how the level errors took place.

Keywords