콘크리트 구조체의 수평 이어치기 처리방법별 부착성에 관한 실험적 연구

An Experimental Study on Bond Properties the ways of Disposal Horizontality Placing Joint of Concrete Structure

  • 발행 : 2006.11.18

초록

Because do placing joint after smallest $1{\sim}3$ day about concrete that is placed beforehand in field, it is difficult that remove laitance happening harden concrete. This laitance happens a problem of bond properties, deterioration in strength. In this research got following conclusion as result that do research about bond properties the way of disposal placing joint. Air Jet is loft interior and exterior. Water Jet appeared that laitance Removal Capacity is superior to dimension within 5%. Deterioration in strength is measured 37% by splitting tensile strength test result by laitance. Deterioration in strength by laitance do more than 30% that removal of laitance is predicted must consist necessarily at concrete horizontality placing joint stroke.

키워드