This study was progressed to value of Bi2212 tubes uniformity depend on cooling conditions. The tube from 150 mm in length, 30 mm in O.D., 20 mm in I.D., 5 mm in thickness was combined with electrodes by 3 sections. The tube from 60, 70 mm in length, 30, 50 mm in O.D., 20.4, 40.4 mm in I.D., 4.8 mm in thickness was in controled of cooling rate by a heat exchanger. Bi2212 tubes were fabricated by Centrifugal Forming Process (CFP) and they were annealed at $840^{\circ}C$ for 80 h in oxygen atmosphere. The tube from 150 mm in length was analyzed by EFDLab of NIKA to show cooling rate and temperature distributions. When the tube was cooled for 100s, the temperature distributions was $663^{\circ}C$ in the middle, $500{\sim}647^{\circ}C$ in inlet, $598{\sim}647^{\circ}C$ in the other side. Electric characteristics from $I_c$ was 450 A in the middle, 650 A in inlet, 600 A in the other side. Electric characteristics by a heat exchanger showed the more fast cooling rate, the more high $I_c$.