Development and Its Characteristics of a Dissipation Factor Standard
손실계수 표준기 제작 및 그 특성
- Kim, Han-Jun (KRISS) ;
- Kang, Jeon-Hong (KRISS) ;
- Han, Sang-Ok (ChungNam Univ.)
- Published : 2006.06.22
Abstract
A dissipation factor standard of decade type having the range of 1 to 0.0001 at the frequency of 1 kHz and 10 kHz was fabricated using "T" networks combined R and C components. The values of the fabricated dissipation factor standard were adjusted within 1% of the nominal values at 0.0001 dial range and 0.05% at the others. This dissipation factor standard is used as a working standard for calibration of a impedance measurement meter at KRISS and as a primary standard of dissipation factor field at NML-SIRIM in Malaysia.