3D Depth Measurement System based on Parameter Calibration of the Mu1ti-Sensors

실거리 파라미터 교정식 복합센서 기반 3차원 거리측정 시스템

  • 김종만 (전남도립남도대학 컴퓨터응용전기과) ;
  • 김원섭 (전남도립남도대학 컴퓨터응용전기과) ;
  • 황종선 (전남도립남도대학 컴퓨터응용전기과) ;
  • 김영민 (전남도립남도대학 컴퓨터응용전기과)
  • Published : 2006.05.19

Abstract

The analysis of the depth measurement system with multi-sensors (laser, camera, mirror) has been done and the parameter calibration technique has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance.