The Passenger Evacuation Simulation Using Fluent and EXODUS

Fluent 와 EXODUS를 이용한 승객피난 시뮬레이션

  • 장용준 (한국철도기술연구원, 환경화재연구팀) ;
  • 박원희 (한국철도기술연구원, 환경화재연구팀) ;
  • 이창현 (한국철도기술연구원, 환경화재연구팀) ;
  • 정우성 (한국철도기술연구원, 환경화재연구팀)
  • Published : 2007.11.08

Abstract

The simulation analysis of fire-driven flow and passenger evacuation in Daegu subway station, Chung-Ang, have been performed. The first location of outbreak of fire is inside passenger car in the third basement in Chung-Ang station. The smoke flow in the second and third basement has been analyzed using FLUENT 6.2. The CO(carbon monoxide) and temperature distribution in the train units and station platform have been obtained and transferred to input data for evacuation simulation. The highest temperature in the train units was 1500K. For the simulation of passenger evacuation, EXODUS has been used for whole basements (level 1${\sim}$ level 3) in the station. Total number of people was assumed to be one thousand and 640 were placed inside train and 360 were placed outside train. In evacuation simulation, an average of 135 passengers were killed and an average time to evacuate takes 10min 19sec. The main evacuation routes used by passengers were investigated and the cause of death was identified by evacuation simulation.

2003년 대구 지하철(중앙역) 화재 사건 당시의 화재 유동 및 승객 피난 시뮬레이션을 수행하였다. 화재 발생 첫 지점은 중앙역 지하 3층 객차 내부이며, 지하 3층과 지하 2층의 화재 및 연기 유동을 FLUENT 6.2를 이용하여 수치해석 하였다. 화재 객차 및 승강장에서의 이산화탄소 및 온도분포를 예측하였으며, 수치해석을 통하여 구해진 data는 승객 피난 시뮬레이션(EXODUS)의 입력 인자로 사용되었다. 수치해석에서 가장 높은 온도는 1500K로 조사되었다. EXODUS를 이용하여 지하 3층에서 지하1층까지 승객 피난 시뮬레이션이 수행되었으며, 총 피난 승객은 1000명으로 가정하였다. 이중 640명은 객차 내부에, 360명은 승강장에 존재하는 것으로 하고 계산을 수행하였다. 피난 시뮬레이션 결과 135명이 사망하였으며 이는 대구 화재 사고결과에 비교적 근접하는 수치이다. 또한 평균 피난 시간은 10분 19초로 조사가 되었다.

Keywords