The number of transformers and the size of transformers in inverter using 3-phase transformer could be reduced compare with a multi-level inverter using single phase transformer. but still the 3-phase transformer inverter needs many switches. In this study, we proposed the isolated multi-level inverter using 3-phase transformers and common arm. Also, the equal-area method is used to calculate conduction angle with switching frequency equal to output fundamental frequency and it can reduce harmonics component of output voltage and switching loss. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.