Proceedings of the Korean Geotechical Society Conference (한국지반공학회:학술대회논문집)
- 2008.03a
- /
- Pages.1106-1116
- /
- 2008
Laterally Loaded Behavior of Short Drilled Shaft Foundation for Single-Pole Structures
단주 구조 송전탑 기초의 횡방향 거동에 관한 연구
- Choi, Ho-Young (Dept. of Civil & Environmental Engineering, KAIST) ;
- Kim, Yeong-Hun (Geotechnical Engineering Team, Hyundai Institute of Construction Technology) ;
- Lee, Seung-Rae (Dept. of Civil & Environmental Engineering, KAIST) ;
- Kim, Dae-Hak (Unicorn Technical Institute(UTI)) ;
- Kim, Dae-Hong (KEPRI, KOPEC)
- 최호영 (한국과학기술원 건설 및 환경공학과) ;
- 김영훈 (현대건설 기술개발원 토목기술부 지반팀) ;
- 이승래 (한국과학기술원 건설 및 환경공학과) ;
- 김대학 (유니콘 기술연구소) ;
- 김대홍 (한국전력공사 전력연구원)
- Published : 2008.03.28
Abstract
Single-pole transmission structures which are supported by drilled shaft foundations are usually subjected to large overturning moments with modest vertical and lateral loads. To analyze the behavior of the drilled shaft under such loading conditions, an analytical model was developed based on beam-column and subgrade reaction methods. Field model tests were performed to calibrate the developed analytical model in which additional subgrade spring models were adopted. The field test results estimated from the calibrated analytical model were compared with those calculated by one spring model and other commercial program. According to the comparison study, the developed analytical model was proven to be a useful tool to analyze the laterally loaded behavior of foundations for single-pole structures.
Keywords