PSD Door Response Time Improving Method in Train Manual Operation Mode

수동운전방식에서의 PSD 출입문 신호반응 시간 개선 방안 연구

  • 이무호 (서울메트로 기술본부 전자팀) ;
  • 김찬겸 (서울메트로 기술본부 전자팀) ;
  • 이석종 (서울메트로 기술본부 전자팀) ;
  • 이수영 (서울메트로 기술본부 전자팀)
  • Published : 2008.06.12

Abstract

Platform Screen Door(PSD) has been installed and operated at seoul subway line $1\sim4$ in the manual train operation mode(ATS/ATC) by SeoulMetro since 2005. SeoulMetro uses the wireless (RF) communication system and the train door detection system for the link between the train and PSD doors opening/closing motion in the manual train operation mode. For the convenience and safety of passengers, the train doors and the PSD doors opening/closing shall be synchronized as much as possible. In ATO(Automatic Train Operation) mode which provides the interface between train control system and PSD system, ATO signaling system makes the train doors and PSD doors open/close command signals systematically, so PSD doors can be opened/closed almost simultaneously with the train doors. But, in the manual train control(ATS/ATC) mode, PSD system needs to detect the train doors open/close operation and make PSD open/close command signals to actuate PSD doors. These PSD open/close commanding process cause time delay of PSD doors opening/closing motion in response to the train doors opening/closing motion. Sometimes the response delay time can be over 1 second, which is not proper to operate PSD, and need to be reduced This paper presents the reduction method of the PSD response delay time to improve the convenience and safety of passengers.

Keywords