Numerical Investigation on Smoke Behavior in Rescue Station for Tunnel Fires

철도터널 화재 시 구난역 내의 연기거동에 대한 수치해석 연구

  • 홍사훈 (중앙대학교 대학원 기계공학과) ;
  • 유홍선 (중앙대학교 기계공학부) ;
  • 이성혁 (중앙대학교 기계공학부)
  • Published : 2008.06.12

Abstract

The present study performed numerical investigation to analyze the smoke behavior in the rescue station by using the commercial CFD code (FLUENT Ver 6.3). The present study adopted a 10MW ultrafast mode for simulation, and it also used the MVHS(Modify Volumetric Heat Source) model modified from the original VHS(Volumetric Heat Source) model in order to treat the product generation and the oxygen consumption under the stoichiometric state. In addition, the present simulation includes the species conservation equation for the materialization of heat source and the estimation of smoke movement. From the results, the smoke flows are moving along the ceiling because of thermal buoyancy force and as time goes, the smoke gradually moves downward at the vicinity of the entrance. Moreover, without using ventilation, it is found that the smoke flows no longer spread across the cross-passages because the pressure in the non-accident tunnel is higher than that in the accident tunnel.

Keywords