Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement

부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가

  • 박대원 (한국해양대학교 전기전자공학부 대학원) ;
  • 최수연 (한국해양대학교 전기전자공학부 대학원) ;
  • 최재성 (한국해양대학교 전기전자공학부 대학원) ;
  • 길경석 (한국해양대학교 전기전자공학부) ;
  • 이강원 (한국철도기술연구원 바이모달수송시스템연구단)
  • Published : 2008.06.12

Abstract

In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

Keywords