The Effect of Air Impurities on the PEMFC Performances

공기에 포함된 불순물에 의한 PEMFC 운전 성능 변화

  • Published : 2008.05.22

Abstract

The effect of air impurities on PEMFC performances were studied using electrochemical analysis, such as OCV monitoring, polarization, constant current operation, and electrochemical impedance spectroscopy. The nitrogen dioxide in air lowered the operation voltage at 1 A/$cm^2$ by 160 mV (10 ppm) and 227 mV (100 ppm), while the carbon monoxide effect was relatively not significant (30 mV at 100 ppm). For both nitrogen dioxide and carbon monoxide, the performances were largely recovered when pure air was provided again. Further study for additional air impurities and simulated air are under progress to provide fundamental data for the design of fuel cell vehicles.

Keywords