창호 및 벽체의 단열성능에 따른 건물에너지효율등급 평가 연구 -공동주택을 중심으로-

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Window and Wall in Apartment Houses

  • 김치훈 (경북대학교 건축공학과/KIER) ;
  • 안병립 (경북대학교 건축공학과/KIER) ;
  • 김지연 (인하대학교 건축공학과/KIER) ;
  • 장철용 (한국에너지기술연구원)
  • 발행 : 2009.06.25

초록

According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.