환경변화에 따른 핀-관, PF 열교환기 적용 공조기 성능 특성 실험 연구

Performance Characteristics on Environment Change of A/C applied Fin-tube and PF Heat Exchangers

  • Park, K.M. (Department of Mechanical Engineering, Sunmoon University) ;
  • Um, U.S. (Department of Mechanical Engineering, Sunmoon University) ;
  • Kwon, Y.C. (Department of Mechanical Engineering, Sunmoon University) ;
  • Lee, S.J. (Korea Institute of Industrial Technology)
  • 발행 : 2009.06.25

초록

In the present study, performance characteristics on environment change of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP changing an outlet air velocity, an indoor/outdoor temperature and a relative humidity were obtained. Air-enthalpy calorimeter was used. As the air velocity, indoor temperature and relative humidity increase, capacity and COP increase. PF A/C has smaller refrigerant weight than the fin-tube A/C. The performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin.

키워드