A Study on Thermal & Electrical Performance of Glazings with DSC modules

염료감응태양전지(DSC)를 적용한 Glazing의 구성에 따른 단열 및 전기 성능 분석

  • kim, Ji-Seong (Dept. of Architecture Eng., Graduate School, Kongju National University) ;
  • Park, Se-Hyeon (Dept. of Architecture Eng., Graduate School, Kongju National University) ;
  • Kang, Jun-Gu (Dept. of Architecture Eng., Graduate School, Kongju National University) ;
  • Kim, Jun-Tae (Dept. of Architecture Eng., Kongju National University)
  • 김지성 (공주대학교 건축학과 대학원) ;
  • 박세현 (공주대학교 건축학과 대학원) ;
  • 강준구 (공주대학교 건축학과 대학원) ;
  • 김준태 (공주대학교 건축학부)
  • Published : 2011.11.24

Abstract

Recently, more attention has been paid to DSC(Dye-sensitized Solar Cell) with the potential of glazing applications. The aim of the study is to analyze thermal and electrical performance according to composition of glazing with DSC. For this study, the electrical and thermal performance of glazing with DSC modules were measured and their result were compared. The measurement were performed according to the KS L2525 and with a solar simulator of DSC modules. The result show that the U-value of the DSC double glazings with clear glass and low-e glass were 2.78 $W/m^2K$ and 1.70 $W/m^2K$, respectively. The electrical measurement indicated that the electrical efficiency of the DSC double glazings with clear glass and low-e glass decreaced by 9.9% and 13.3%, respectively, compared to the DSC medules electrical performance.

Keywords