A study on surface resistivity of GFRP reinforced precast slab track

유리섬유보강 슬래브의 표면저항특성 고찰

  • 문도영 (고려대학교 건축.사회환경공학부) ;
  • 지광습 (고려대학교 건축.사회환경공학부) ;
  • 이승정 (고려대학교 건축.사회환경공학부) ;
  • 김유봉 (삼표이앤씨(주). PSTS팀) ;
  • 백인혁 (삼표이앤씨(주). PSTS팀)
  • Published : 2011.10.20

Abstract

Steel bar is used for as a reinforcing material in a concrete slab track. Bacuase the steel re-bar could provide passes for current transition, all the cross points of steel re-bars should be insulated by using plastic materials. This is due to the loss of signal intensity of track-circuit. In this study, GFRP bars are adopted in place of the traditional steel reinforcing bars for a concrete slab track to minimize the loss of the signal intensity. In order to evaluate the replacing effect on eletrical characteristic of slab track, measurements of surface resistivity are conducted on steel and GFRP reinforced precast slab tracks. In the results, the GFRP reinforced slab strack shows the higher resistivity than the steel reinforced slab track.

Keywords