Comparison of Ultrasonic Paths for Flow Rate Measurement

유량측정을 위한 초음파 전파경로 비교

  • 김주완 (숭실대학교 대학원 기계공학과) ;
  • 박춘광 (숭실대학교 대학원 기계공학과) ;
  • 김대종 (숭실대학교 대학원 기계공학과) ;
  • 김진오 (숭실대학교 공과대학 기계공학과) ;
  • 김동현 (한국파나메트릭스(주))
  • Published : 2014.10.29

Abstract

The paper deals with the accuracy comparison between two kinds of ultrasonic paths for flow rate measurement. In the Z-path, two transducers are installed on the opposite side of each other on a pipe, and the ultrasonic waves generated of one transducer propagate and arrive at the other one only through refraction. In the V-path, two transducers are installed on one side of a pipe, and the ultrasonic waves reflected at the inner wall of the pipe are received. The backgrounds were established to select one path to fit the usage by considering the advantages and disadvantages.