Deciding the Appropriate Combination Ratio for FA and BS in High-Intensity Cement Mortar

고강도 시멘트 모르타르에서 FA 및 BS의 적정조합비율 결정

  • Published : 2016.10.21

Abstract

This study analyzes the engineering characteristics of mortar according to admixture replacement ratios in cement mortar in a high-intensity ternary system, and changes in FA and BS combination ratios, in order to deduce the optimal combination ratio of FA and BS. Results showed that due to the characteristics of unhardened mortar, flow rate increased with the increase in admixture replacement and FA combination ratios, whereas air quantity decreased and setting time was delayed. Due to the characteristics of light mortar, compression strength decreased at early material ages as the overall combination ratio of FA increased. The FA : BS combination ratio was 2 : 3 on day 28 of material age, proving the best and potentially optimal combination ratio.

Keywords